Armature relays ni switches help national instruments. Refer to devices for a list of valid relay names for the switch module. The cfpcbx connector block has connections for the eight relay channels on the cfp. Software, drivers and tech support for cytec switching systems. National instruments distributor mouser electronics is stocking national instruments products and software. Niswitch support from instrument control toolbox hardware. Summary of contents for national instruments relay module sccrly01 page 1.
Simulation results show that the developed relay model is quite flexible, efficient and can be used in realtime. National instruments relay module sccrly01 user manual pdf. Nov 27, 2017 installing labview usb rs232 rs485 relay controller instrument driver. Some switch model revisions were built using different relays, contact national instruments to find out which relay was used on a specific device. You can have your systems up and running in minutes to acquire static and dynamic signals from a variety of sensor types without any programming. There is a significant amount of autonomyempowerment allowed whilst high levels of support support around you. Each relay is latching with low onresistance and low thermal offsets. National instruments offers a wide variety of switch modules in several topologies covering a large span of voltage and current ratings. The toolbox supports niswitch devices using the niswitch driver version 4.
When the application opens, locate the help menu at the top of the screen. The media on which you receive national instruments software are warranted not to fail. Development of overcurrent relay model and power system. Armature relays are a type of electromechanical relay made of coils, an armature mechanism, and contacts. Ni 2816 relay replacement ni switches help national. Complete the following sets of steps to locate and replace a failed relay on your ni switchblock card.
Download instrument drivers for ni and thirdparty hardware. National instruments sc2062 electromechanical relay digital output board. This relay output module is designed to be mounted on a cfpbpx compact fieldpoint backplane, which delivers operational power to the module. Modeling efforts to establish a hil platform using national instruments devices have been presented here. These links are for labview and labwindows drivers to run cytec switches from. National instruments 8channel solidstate relay ssr. This project provides students with the tools and activities to learn the properties, principles of operation, and interface theory of relays. The user can store a list of switch associations in memory on board the switch module and afterward. You wont be using just software to control a relay.
Used pxi2565 switch module in very good condition, all channels working at near ni specification for initial resistance value. Ni pxi2565 16channel high power relay switch module. Tracking relay usage on ni switch products national. Then, i also want to suggest ni to manufacture a similar card that do not limit the number of relays or at least up to 4. Sel products, systems, services, and training make electric power safer, more reliable, and more economical. National instruments general purpose relays for sale ebay. Ni package manager is included with newer ni software downloads. Ni pxi2575, ni pxie2575 data sheet national instruments. Students complete activities where they implement a circuit to interface myrio with a relay, and use labview to set the relay on and off. National instruments from daily tasks to grand challenges, ni helps engineers and scientists overcome complexity to exceed expectations.
The switch may have any number of contacts in multiple contact forms, such as make contacts, break contacts, or combinations thereof. View online or download national instruments relay module sccrly01 user manual. Customers in nearly every industryfrom healthcare and automotive to consumer electronics and particle physicsuse nis integrated hardware and software platform to improve the world. Switch executive and exclusions with single pole double. The media on which you receive national instruments software are warranted not to fail to execute programming instructions, due to defects in materials and workmanship, for a period of 90 days from date of shipment, as evidenced by receipts or other documentation. Students complete activities where they implement a circuit to interface myrio with a relay. The magnetic relay is a coil with a specified inductance lc, in henrys that causes a contact to open or close when a specified current ion, in a charges it.
Go to help find examples hardware input and output modular instruments niswitch open the example switch controlling an individual relay niswitch. Each channel provides access to a solid state relay for switching voltages up to 60 vdc, 30 vrms with switching current of up to 1. National instruments cfprly421 compact fieldpoint relay module easy clickquotebuy today. For quick reference, every channel features an led to indicate the state of that channel. The ni pxi2565 has 16 independent form a nonlatching socketed relays, which can be replaced easily in the field. Software all national instruments pxi switch modules are shipped with niswitch, an ivicompliant driver that offers complete functionality for all switch modules. Chameleon from pvi systems is an intuitive and easytouse yet powerful turnkey daq program developed to take full advantage of hardware from ni. National instruments 183064b01 electromechanical spdt. Pxi2569 national instruments relay module apex waves.
Software and driver downloads national instruments. Experienced expert engineers that specialize in your application. Pxi relay modules use a variety of relay types, including electromechanical armature relays, reed relays, fieldeffect transistor fet relays, and solidstate relays, each with their own benefits, allowing you to choose a set of relays that fit your requirements. For additional assistance in configuring, programming, and managing higher channelcount switching systems, ni switch executive software provides an easytouse, intelligent switch. Relays are classified by their number of poles and number of throws. National instruments corporation, or ni, is an american multinational company with international operation. Scxi1160 obsolete status has been announced by national instruments, but the module will still be available for purchase and repairs by. View online or download national instruments 8channel solidstate relay ssr digital output ni 9485 operating instructions manual. Hello, i have an experiment where a controller probe needs to be switched onoff to take measurement every 30 seconds or so. The pole of a relay is the terminal common to every path. National instruments software compatibility pickering.
To make software work with spdts and ivi requirements, ivicompliant driver software typically stores the state of spdt relays in a unique and potentially confusing manner. Im pretty new to switches and i dont know if there exists one but im trying to look for a relay switch that can be programmed and controlled via labview so that i can automate the process. Installing labview usb rs232 rs485 relay controller. See relay count in ni switches help file located on the system under start.
Pxi relay modules consist of multiple independent relays, such as singlepole singlethrow spst, singlepole doublethrow spdt, and doublepole doublethrow dpdt relays. National instruments cfprly421 in stock, we buy sell. Feb 08, 2016 consider a modular solution if your application requires a software approach to simplify development, a health monitor tool to track relay usage, or synchronized timing across multiple instruments. I recommended this card against a card of another brand known to work to make the new system as homogeneous as possible. National instruments provides a number of software products for instrument control and pickering products are compatible with the vast majority of them. National instruments software compatibility pickering interfaces. May 14, 2018 not all switch modules support this function. Highcurrent, highvoltage, or multipole rf switches all fit into the realm of possibilities. Each position where the pole can connect is called a throw. However, which editions of windows 10 are supported by ni software. This model includes labview and labwindowscvi, which are innovative program development software bundles for information acquisition and control. Max configuration to use pickering interface switches with the ni switch executive. Free shipping on many items browse your favorite brands.
National instruments usb6525 digital io relay card ni daq. I have a c series relay module in the 948x family, and i want to program it to provide a digital output using either daqmx tasks or daq assistant. National instruments relay driver the national instruments pxi2567 and scxi1167 are designed to be 64channel, multipurpose relay drive modules, capable of driving many types of external relays. The sc2062 is an electromechanical relay board with two different part numbers. If you do not have the driver installed, the help file can also be found in relay count help file. The c series relay output module enables you to switch up to eight signals at 60 v maximum dc switching voltage and up to 250 v of maximum ac switching current. In addition, with the open communication architecture, the unit can also be used with thirdparty software programs such as national instruments labview. National instruments 8channel solidstate relay ssr digital output ni 9485 pdf user manuals. Additional information if you want to increase the amount of pins on a relay you will need to add another relay in the design, replacing the one already in place. Driving external relays with national instruments xx67.
Contact national instruments to find out which relay was used on a specific device. Relay counts are stored on your ni switch hardware in nonvolatile storage such as eeprom or flash, and are backed up periodically as well as on system shutdown. In comparison to the total number of users, most pcs are running the os windows 7 sp1 as well as windows 10. Aug 19, 2011 download omcmc256, a labview ethernet plug and play projectstyle instrument driver for a high precision relay test set and universal calibrator from omicron, models. Download ri1260, a labwindowscvi,measurement studio for visual studio vxivme plug and play instrument driver for a relay actuator,signal switching relay actuator module,20channel dpst switch,signal muxscanner,highdensity signal scannermux, relay mux,signal matrix module,200 mhz relay mux,1 ghz terminated rf mux from racaldana, models. Editions of windows 10 supported by ni software national. Solution there are some examples installed by the niswitch driver that show how to control individual relays. You can supply a single relay name or commadelimited list of relay names to control these relays. Ni equips engineers and scientists with systems that accelerate productivity, innovation, and discovery. The ni pxi relay driver module controls external relays using an internal power source or external power source. The example below is comprised of two relays with their coms connected together hardwired together. National instruments pxi2520 relay module for sale online.
The relay will remain on as long as the current in the circuit is greater than the holding current i hd. Systemlink software lets engineering teams managing tasks such as software deployment, device configuration, health and test monitoring, and data management and visualization. This guide contains instructions for installing labview usb rs232 rs485 relay controller instrument driver on your development environment. This relay switch module does not have access to the analog backplane to safeguard the backplane from faults when high voltages are present on the relay contacts. Launch the national instruments software you wish to identify. Once your test data is in matlab, you can analyze and visualize that. In the relay the signal at the control input determines the output of the. Scxi1160 national instruments relay switch module apex. The ni pxi2522 generalpurpose switch module part number. While about 53% of users of national instruments software come from the united states, it is also popular in india and united kingdom. When the coil is energized, the induced magnetic field moves the armature. National instruments cfprly421 relay output module for compact fieldpoint.
The unit can be operated either manually via the builtin touchscreen user interface stvi, or placed under full computer control via the rtms, relay test management software, running on a pc. Unexpected power removal could prevent proper backup of the relay counts, resulting in the possible loss of a few minutes of relay count data. National instruments sc2062 8channel electromechanical relay sc2062 the sc2062 has eight electromechanical relays controlled by digital output signals from ni daq devices. For example, a singlepole singlethrow spst relay has one pole and one throw, as illustrated in the following. Connect or disconnect individual relays to simplify wiring in automated test systems. I want to place some electromechanical relays on multisim but all that i find are regular relays and relay drivers. Common applications include data acquisition, instrument control and machine vision. It is right now a mechanical switch that needs to be flipped onoff. Pxi2522 national instruments relay module apex waves. Some switch model revisions were built using different relays. Combining the best of opalrt and ni products and software to extend our offering with even more accessible, cuttingedge, realtime simulation technology. You can supply a single relay name or a commadelimited list of relay names to control these relays. Relay interface circuit suitable for internal pulldown resistors on ni myrio msp connector c. National instruments uses a dry reed relay and the inert gas inside the capsule is typically nitrogen.
Headquartered in austin, texas, it is a producer of automated test equipment and virtual instrumentation software. Assetrelay 616 augustemondoux gatineau quebec j9j3k3 canada email us. National instruments ni pxi2569 relay switch card, 100ch. Pxi2570 national instruments relay module apex waves.
User guide user guide sccrly01 relay module the sccrly01 contains one singlepole doublethrow spdt nonlatching relay capable of switching 5 a at 30 vdc when using an sc2345 or sc2350, or 250 vac when using an scc68. If you do not have the driver installed, the help file can also be found in relay count. How to control an individual relay of my niswitch card. Each relay comprises a normally closed nc, normally open no, along with a common com terminal. Through these activities, students follow steps to demonstrate correct operation of the relay, watch videos. Nidaqmx issue details i have a c series relay module in the 948x family, and i want to program it to provide a digital output using either daqmx tasks or daq assistant. Relay also pays for people to complete their degrees in software engineering. Ni does sell relay digital cards in several form factors. On the left are the default physical relay states in hardware. Provides output signals from electromechanical and solid statefet relays for compactdaq or compactrio systems. For some applications, relay drivers are the ideal choice when the current, voltage or frequency requirements for relays exceed those found in the existing switch modules or for relays embedded in a test system. Sel provides complete power system protection, control, monitoring, automation, and integration for utilities and industries worldwide. Issue details my product is listed as supported in the national instruments product compatibility for microsoft windows 10 guide.
See relay count in ni switches help file located on the system under startall programsnational instrumentsniswitchdocumentationni switches help. It consists of a set of input terminals for a single or multiple control signals, and a set of operating contact terminals. The ni pxi2570 optimizes relay density in one pxi slot. Relay offers an integrated suite of products including backoffice software and etrading platform for motor, home, commercial vehicle, lifeinvestment, and commercial lines panels. Find or submit cameras that have been tested with ni software. Ground yourself using a grounding strap or a ground connected to your pxi chassis. The ni 9485 is a 8channel solid state relay sourcing or sinking digital output module for any ni compactdaq or compactrio chassis. The following links provide pages with further information. This article discusses relay failures in switching systems and how to locate a defective relay using diagnostic test tools.
If your switch module uses armature relays, consider the factors that affect relay life. This thesis work also proposes a highperformance and lowcost national instruments pxi platform for power system simulations. Pickerings products are compatible with most of the national instruments software tools including labview, labwindows cvi, switch executive and more. Setup max to use pickerings switches with ni switch executive. National instruments usb6525 digital io relay card ni.
Get the best deals on national instruments general purpose relays when you shop the largest online selection at. National instruments will, at its option, repair or. You need hardware, to interact with the software to do stuff. There is also an entry in the instrument driver software modules folder. Tracking relay usage on ni switch products national instruments. This relay board can be mounted to sit on a workbench or in a rackmount chassis with a flat plastic cover or metal wraparound cover. National instruments sc2062 8channel electromechanical relay. The reed switch is composed of two overlapping ferromagnetic blades hermetically sealed within a glass capsule that is filled with an inert gas. Relay products are the market standard in ireland, and the company serves more than 400 customers with over 3,000 insurance professional users in the irish market. National instruments software is a program developed by national instruments. Each channel provides access to an electromechanical relay for switching signals up to 60 vdc 1 a or 250 vrms 2 a, features channeltochannel isolation, and has a led that indicates the status.
Finding the serial number of my national instruments. Labview is a programming language which is software. Pxi2568 national instruments relay module apex waves. Download software products, including programming environments, application software, and software suites, or find software addons. About the dialog box that appears will display software. The pxi relay driver module controls up to 64 external relays with up to 50 vdc or 600 ma per channel drive capacity when using an external power supply. Reed relays reed relays are made up of coils wrapped around reed switches.